Rack PDU Product Lines

Four grades on one hardware platform — metered, switched, outlet-metered and AI rack power. Filter the range by feed, phase, outlet mix and control grade below, or send the load list and an engineer will match the build.

Open the selector

PDU selector

Four filters. One SKU family.

Pick your feed (phase and input current), your outlet plan and the control grade — the table narrows as you go. Every row is a standard build we keep on the line; combinations that come back empty are usually a 14-30 day custom job, not a refusal.

SeriesPhaseInputOutletsGradeTypical rack
M-Series1φ 230V16A IEC 6030912 × C13MeteredNetwork closet, up to 3.6kW
M-Series1φ 230V16A IEC 603098 × C13 + 2 × C19MeteredCompute + storage mix
M-Series1φ 230V32A IEC 6030924 × C13MeteredDense 1φ enterprise rows
O-Series1φ 230V16A IEC 603098 × C13 + 2 × C19Outlet-MeteredLab benches, per-device logs
S-Series1φ 230V16A IEC 603098 × locking C13SwitchedUnattended IT closets
S-Series1φ 230V32A IEC 6030920 × C13 + 4 × C19SwitchedBranch sites, reboot from NOC
O-Series1φ 230V32A IEC 6030924 × C13Outlet-MeteredColocation tenant billing
O-Series1φ 230V32A IEC 6030920 × C13 + 4 × C19Outlet-MeteredPer-circuit cost allocation
S-Series3φ 400V WYE32A IEC 6030918 × C13 + 6 × C19SwitchedEU 400V rows to 22kW
S-Series3φ 400V WYE63A IEC 6030924 × C19Switched22-36kW feeds, HPC restarts
O-Series3φ 415V WYE63A IEC 6030930 × C19Outlet-MeteredMining shelves, per-shelf kWh
M-Series3φ 400V WYE32A IEC 6030924 × C13MeteredMonitoring-only 3φ rows
No SKU matches that combination yet — this table lists platform stock builds. Every combination is still manufacturable as a configured order: or ask for a custom build.

NEMA builds (L5-30P, L6-30P, L21-30P) mirror every row above. The AI Rack Power X-Series starts from the O- and S-Series platforms with the full sensor and analytics stack — see AI Rack Power, or the plug-by-plug charts in Selection Guides.

One platform, four grades

Mix grades in one row without new tooling

lines 4 feed 16-63A outlets 8-48 max output 36kW daisy-chain ×8 / IP FOB band $60-700

All four lines share one firmware image, one SNMP MIB and one mounting system, so a metered row and a switched row read identically in your NMS. That is deliberate — mixed-grade racks are the norm in real deployments, not an exception we tolerate.

Grade comparison

Five grades, side by side

Basic units distribute power and nothing else; every step up adds a specific capability you can point to on a datasheet. FOB bands below reflect standard-config builds — OEM customization moves them, not the platform.

DimensionBasicMeteredOutlet-MeteredSwitchedSwitched + OM
Unit / phase metering (V, A, kW, kWh, PF)±1%±1%±1%±1%
Per-outlet current±1%±1%
Per-outlet kWh±2%, 15-min freeze±2%, 15-min freeze
Per-outlet switching100k-cycle relays100k-cycle relays
Sequenced startup0-999s delays0-999s delays
Environmental sensor portsRJ12 ×2RJ12 ×2RJ12 ×2RJ12 ×4
Tenant billingNoInput-level onlyNativeNoNative
Network & protocolsSNMP v1/v2c/v3, HTTP(S)SNMP v3 + RESTSNMP v3 + RESTSNMP v3, REST, MQTT
Typical feedIEC 60309 16-32A16-63A, 1φ/3φ16-63A, 1φ/3φ16-63A, 1φ/3φ32-63A 3φ
Typical outlet count8-248-3220-488-3224-48
FOB price band$60-120$120-260$260-500$200-450$400-700
Best fitBudget refits, channel stockEnterprise monitoringColocation billingEdge and lights-out sitesFinance and premium hosting

Still torn between two grades? The decision tree in Metered vs Switched vs Outlet-Metered settles it in about four minutes.

Send the load list, get the grade

Feed, phase, outlet count and quantity — an engineer answers within 48 hours with a matched series, a datasheet and FOB pricing. Standard-config samples ship in 3-7 days.