Rack power distribution, built to drawing
IDCPDU is the trade mark. Ningbo DCDU Power Distribution Equipment Co., Ltd. is the legal entity that builds the units and holds the certificates.
- Trade mark
- IDCPDU
- Legal entity
- Ningbo DCDU
- Order basis
- drawing or sample
- Testing
- 100% electrical
- Documents
- per line
Two names, and what each one covers
The trade mark is what you buy under. The legal entity is what signs the certificate, the drawing and the test record. Both appear on the documents that travel with a unit.
Certificates are held by Ningbo DCDU Power Distribution Equipment Co., Ltd.- Trade mark
- IDCPDU
- Legal entity
- Ningbo DCDU Power Distribution Equipment Co., Ltd.
- Certificate holder
- Ningbo DCDU
- Site
- Cixi, Ningbo, Zhejiang, China
- Order basis
- customer drawing or sample
- Product range
- PDU, smart PDU, ATS, server cabinets, EV charging and distribution units
- Metering platform
- ±1%, 1 grade energy
- Reporting
- SNMP, Modbus, web server, SMTP
- Compliance
- IEC / NEMA; CE, RoHS, and UL Recognized Component (UL 62368-1) as applicable
- Testing
- 100% electrical testing
- Documents
- specification sheet per line, outline drawings
- Reply window
- within 12 hours, working days
One holder on every document
A quotation, an outline drawing and a certificate should name the same party. Here that party is Ningbo DCDU Power Distribution Equipment Co., Ltd., and IDCPDU is the mark used on the site and the unit.
Document set: quotation · drawing · test record · certificate titlesBuilt to a drawing, not to a catalogue number
A rack PDU is decided by the feed it sits on. Outlet type, outlet count, current per feed and metering depth come from your drawing or a sample unit, and the configuration is fixed before anything is cut.
- Input
- drawing or sample
- Outline drawing
- per unit and mounting orientation
- First article
- built and checked before series
- Revision control
- drawing revision confirmed in writing
Certificates, by title and holder
Scans are held for the management systems and for product conformity. The UL evidence is a component certificate, so the wording used here is UL Recognized Component, certified to UL 62368-1.








What the range covers, and where each line is used
Four families carry most orders: PDU and smart PDU, ATS, server cabinets, and EV charging and distribution units. ATS and cabinets are quoted from the same drawing package as the PDU.
| Line | What it does | Usual duty |
|---|---|---|
| Metered PDU | total per feed, ±1% | data hall, server room |
| Switched PDU | relays per outlet or group | remote reboot |
| Per-outlet monitored | current transformer per outlet | colocation billing |
| ATS | dual input, automatic transfer | single-corded equipment |
| Vertical / zero-U | 0U column, no rack units used | dense cabinets |
| Horizontal / 1U | rack-mounted, mixed outlets | standard racks |
| Server cabinet | enclosure with PDU provision | edge and branch rooms |
| EV charging and distribution | AC charging and distribution units | fleet and building supply |
| Custom assembly | to drawing or sample | OEM programmes |
| Metering accessories | CT kits, sensor inputs | retrofit and upgrade |
| Busbar and cabinets | copper busbar, bolted joints | high-current feeds |
The cabinet follows the PDU
When a cabinet and its PDU are ordered together, the mounting and the cable entry are drawn once. The outlet row, the breaker position and the metering depth stay on the same revision.
Rated example: AC 415V, 20 × 20A · outlets C13 × 36 + C19 × 4The paper behind one unit
Six records carry a build from enquiry to dispatch. Each one names the unit, the revision and the entity that signed it.
Enquiry record
The four lines of electrical data, as received, with the outlet combination and the current per feed. It is the reference if a drawing is questioned later.
Configured quotation
Written in English, priced per line, with the metering depth and switching scope stated. No lead time or minimum quantity figure is published on this site.
Outline drawing
Drawn by unit and by mounting orientation, carrying current, frequency and protection. The revision is confirmed in writing before production.
First article record
The first unit of a series is built and checked against the drawing. Dimensions, outlet order and metering lines are compared before the run continues.
Test record
Every unit is powered and tested: continuity, polarity, insulation and function. Metering readings are compared against a reference and recorded per line.
Certificate titles
Titles and the holding entity travel with the dispatch documents. Numbers are not published on the site, and are shared with the named buyer on request.
Send a drawing, or send a sample
A drawing gives the fastest route to a configured quotation. A sample unit works when the outlet set is easier to show than to describe.
Reply within 12 hours on working days · quotation written per line