About IDCPDU

Rack power distribution, built to drawing

IDCPDU is the trade mark. Ningbo DCDU Power Distribution Equipment Co., Ltd. is the legal entity that builds the units and holds the certificates.

Trade mark
IDCPDU
Legal entity
Ningbo DCDU
Order basis
drawing or sample
Testing
100% electrical
Documents
per line
Identity

Two names, and what each one covers

The trade mark is what you buy under. The legal entity is what signs the certificate, the drawing and the test record. Both appear on the documents that travel with a unit.

Certificates are held by Ningbo DCDU Power Distribution Equipment Co., Ltd.
Trade mark
IDCPDU
Legal entity
Ningbo DCDU Power Distribution Equipment Co., Ltd.
Certificate holder
Ningbo DCDU
Site
Cixi, Ningbo, Zhejiang, China
Order basis
customer drawing or sample
Product range
PDU, smart PDU, ATS, server cabinets, EV charging and distribution units
Metering platform
±1%, 1 grade energy
Reporting
SNMP, Modbus, web server, SMTP
Compliance
IEC / NEMA; CE, RoHS, and UL Recognized Component (UL 62368-1) as applicable
Testing
100% electrical testing
Documents
specification sheet per line, outline drawings
Reply window
within 12 hours, working days
Why the split matters

One holder on every document

A quotation, an outline drawing and a certificate should name the same party. Here that party is Ningbo DCDU Power Distribution Equipment Co., Ltd., and IDCPDU is the mark used on the site and the unit.

Document set: quotation · drawing · test record · certificate titles
Order basis

Built to a drawing, not to a catalogue number

A rack PDU is decided by the feed it sits on. Outlet type, outlet count, current per feed and metering depth come from your drawing or a sample unit, and the configuration is fixed before anything is cut.

Input
drawing or sample
Outline drawing
per unit and mounting orientation
First article
built and checked before series
Revision control
drawing revision confirmed in writing
Rack PDU installed in service, seen from a low three-quarter angle inside a dark equipment aisle with the rack rails and a receding row of closed cabinets out of focus behind it
Evidence on file

Certificates, by title and holder

Scans are held for the management systems and for product conformity. The UL evidence is a component certificate, so the wording used here is UL Recognized Component, certified to UL 62368-1.

ISO 9001 quality management certificate scan naming Ningbo DCDU Power Distribution Equipment Co., Ltd. as holder
ISO 9001Quality management · holder: Ningbo DCDU
ISO 14001 environmental management certificate scan naming Ningbo DCDU Power Distribution Equipment Co., Ltd. as holder
ISO 14001Environmental management · holder: Ningbo DCDU
ISO 45001 occupational health and safety certificate scan naming Ningbo DCDU Power Distribution Equipment Co., Ltd. as holder
ISO 45001Health and safety · holder: Ningbo DCDU
UL component certificate scan for audio, video and information technology equipment, certified to UL 62368-1, held by Ningbo DCDU Power Distribution Equipment Co., Ltd.
UL 62368-1Component certificate · holder: Ningbo DCDU
CE low voltage directive certificate scan issued to Ningbo DCDU Power Distribution Equipment Co., Ltd.
CE, LVDLow voltage directive · holder: Ningbo DCDU
CE electromagnetic compatibility certificate scan issued through TUV to Ningbo DCDU Power Distribution Equipment Co., Ltd.
CE, EMCElectromagnetic compatibility · TUV
Credit evaluation certificate scan issued to Ningbo DCDU Power Distribution Equipment Co., Ltd.
Credit evaluationIssued to the legal entity
CCC certificate scan issued to Ningbo DCDU Power Distribution Equipment Co., Ltd.
CCCProduct conformity · holder: Ningbo DCDU
Certificate numbers are not published here. Titles, standards and the holding entity are available on request.
Product range

What the range covers, and where each line is used

Four families carry most orders: PDU and smart PDU, ATS, server cabinets, and EV charging and distribution units. ATS and cabinets are quoted from the same drawing package as the PDU.

Product lines and their typical duty
LineWhat it doesUsual duty
Metered PDUtotal per feed, ±1%data hall, server room
Switched PDUrelays per outlet or groupremote reboot
Per-outlet monitoredcurrent transformer per outletcolocation billing
ATSdual input, automatic transfersingle-corded equipment
Vertical / zero-U0U column, no rack units useddense cabinets
Horizontal / 1Urack-mounted, mixed outletsstandard racks
Server cabinetenclosure with PDU provisionedge and branch rooms
EV charging and distributionAC charging and distribution unitsfleet and building supply
Custom assemblyto drawing or sampleOEM programmes
Metering accessoriesCT kits, sensor inputsretrofit and upgrade
Busbar and cabinetscopper busbar, bolted jointshigh-current feeds
One drawing package

The cabinet follows the PDU

When a cabinet and its PDU are ordered together, the mounting and the cable entry are drawn once. The outlet row, the breaker position and the metering depth stay on the same revision.

Rated example: AC 415V, 20 × 20A · outlets C13 × 36 + C19 × 4
Documentation trail

The paper behind one unit

Six records carry a build from enquiry to dispatch. Each one names the unit, the revision and the entity that signed it.

  1. Enquiry record

    The four lines of electrical data, as received, with the outlet combination and the current per feed. It is the reference if a drawing is questioned later.

  2. Configured quotation

    Written in English, priced per line, with the metering depth and switching scope stated. No lead time or minimum quantity figure is published on this site.

  3. Outline drawing

    Drawn by unit and by mounting orientation, carrying current, frequency and protection. The revision is confirmed in writing before production.

  4. First article record

    The first unit of a series is built and checked against the drawing. Dimensions, outlet order and metering lines are compared before the run continues.

  5. Test record

    Every unit is powered and tested: continuity, polarity, insulation and function. Metering readings are compared against a reference and recorded per line.

  6. Certificate titles

    Titles and the holding entity travel with the dispatch documents. Numbers are not published on the site, and are shared with the named buyer on request.